(4) Simplified program command list

The command list and parameter list to be used for simplified program function are provided.
No.
Function code
Abbreviation
Command
Enable
End
Completion
1
0
Enable
1
DELy
2
Delay
Enable
AND conditional branch
2
And
3
4
3
or
OR conditional branch
Stitching count AND
5
4
STiA
conditional branch
Stitching count OR
conditional branch
6
5
STio
Jump repeat counter
7
6
JUMP
8
7
SPEd
Rotation speed command
Speed limit command
9
8
LiMi
10
9
LinH
Lswinh command
11
10
TrM
Thread trimming command
12
11
TinH
Tswinh command
13
12
UP
Up stop command
14
13
HS
Needle up/down command
15
14
rSW
Rsw command
Angle AND
16
15
AnGA
conditional branch
Angle OR
17
16
AnGo
conditional branch
18
17
SToP
Stop command
BTsw command
19
18
bT
(Reverse feed
stitching output)
FLsw command
20
19
FL
(Presser lifting output)
Program reset
21
20
rEST
Parameter 1
Output setting
Setting range
Input setting
Setting range
oH.1 to 32
Disabled
Disabled
oL.1 to 32
oH.1 to 32
Disabled
Disabled
oL.1 to 32
iH.1 to 75
oH.1 to 32
Enable
Skip destination step
oL.1 to 32
iL.1 to 75
No. (Sn)
Enable
oH.1 to 32
Enable
iH.1 to 75
Skip destination step
iL.1 to 75
oL.1 to 32
No. (Sn)
oH.1 to 32
iH.1 to 75
Skip destination step
Enable
Enable
oL.1 to 32
iL.1 to 75
No. (Sn)
oH.1 to 32
Enable
Enable
iH.1 to 75
Skip destination step
oL.1 to 32
iL.1 to 75
No. (Sn)
Enable
oH.1 to 32
Disabled
Jump
oL.1 to 32
(Sn)
Enable
oH.1 to 32
Disabled
Speed
oL.1 to 32
(S)
oH.1 to 32
Enable
Disabled
Speed limit
oL.1 to 32
(S)
on/off information
Enable
oH.1 to 32
Disabled
(on/off)
oL.1 to 32
Enable
Disabled
Disabled
oH.1 to 32
oL.1 to 32
oH.1 to 32
Enable
Disabled
on/off information
oL.1 to 32
(on/off)
oH.1 to 32
Enable
Disabled
Disabled
oL.1 to 32
Enable
Disabled
Disabled
oH.1 to 32
oL.1 to 32
Enable
oH.1 to 32
Disabled
Disabled
oL.1 to 32
Enable
Enable
oH.1 to 32
Skip destination step
iH.1 to 75
oL.1 to 32
iL.1 to 75
No. (Sn)
oH.1 to 32
Enable
Enable
iH.1 to 75
Skip destination step
oL.1 to 32
iL.1 to 75
No. (Sn)
Enable
oH.1 to 32
Disabled
Disabled
oL.1 to 32
oH.1 to 32
Enable
Disabled
on/off information
oL.1 to 32
(on/off)
Enable
oH.1 to 32
Disabled
on/off information
oL.1 to 32
(on/off)
Enable
Disabled
Program No. (Sn)
oH.1 to 32
oL.1 to 32
Parameter 2
Setting range
Setting range
Disabled
0:
Delay time (d)
1-999 X 1mS
1 to 25
0 : Waiting for input until
Delay time (d)
conditions are met
1-999 X 1mS
1 to 25
Delay time (d)
0 : Waiting for input until
conditions are met
1-999 X 1mS
Stitching count
0: Command disabled
1 to 25
(C)
(1 to 999 stitches)
Stitching count
0: Command disabled
1 to 25
(C)
(1 to 999 stitches)
Repeat count
0: Unlimited
1 to 25
value
(1 to 999)
(r)
Delay time
0: Delay time disabled
0 to 999
(d)
0 to 999 X 1mS
(X 10sti/min)
0 to 999
Delay time
0: Delay time disabled
(X 10sti/min)
(d)
0 to 999 X 1mS
on/off
Delay time
0: No delay
(d)
1 to 999 X 1mS
Delay time
0: No delay
(d)
1 to 999 X 1mS
on/off
Delay time
0: No delay
(d)
1 to 999 X 1mS
Delay time
0: No delay
(d)
1 to 999 X 1mS
Delay time
0: No delay
(d)
1 to 999 X 1mS
Delay time
0: No delay
(d)
1 to 999 X 1mS
Angle
0: No delay
1 to 25
(A)
1 to 359 degree
Angle
0: No delay
1 to 25
(A)
1 to 359 degree
Delay time
0: No delay
(d)
1 to 999 X 1mS
on/off
Delay time
0: No delay
(d)
1 to 999 X 1mS
Delay time
0: Disabled
on/off
(d)
1 to 999 X 1mS
Disabled
1 to 4
– 57 –
Remarks
Initial value
A command is disabled when the delay time is 0. Other than that, transition to the next step is executed after
lapse of the delay time.
When all the conditions specified in the input setting are met (AND input), transition to the next step is executed.
When input conditions are not met and the delay time is exceeded, jump to the step specified with the skip
destination step number is executed.
When any one of the conditions specified in the input setting is met (OR input), transition to the next step is
executed.
When input conditions are not met and the delay time is exceeded, jump to the step specified with the skip
destination step number is executed.
When all the input setting conditions are met within the setting range of the stitching count setting (AND input),
jump to the step specified with the skip destination step number.
After the predetermined stitching count ends, transition to the next step is executed.
When any one of the input setting conditions are met within the setting range of the stitching count setting (OR
input), jump to the step specified with the skip destination step number.
After the predetermined stitching count ends, transition to the next step is executed.
Jump between specified steps repeats up to the specified repeat number of times.
When the setting value is 0, loop is executed endlessly.
(Caution) Do not execute nested input of this command.
The machine speed can be set.
An operation is always performed when the delay time is 0. Other than that, an operation is performed at specified
speed within the delay time, and the speed command is cancels after lapse of the delay time.
Actual rotation speed will not be equal to or less than the setting value specified in function setting No. 35,
minimum rotation speed, and also will not equal to or more than the setting value specified in function setting
No. 96, maximum rotation speed.
The limit value of the maximum speed of the machine can be specified.
The speed limit is always enabled when the delay time is 0. Other than that, the specified speed limit is enabled
within the delay time, and the speed limit command is canceled after lapse of the delay time.
Actual speed limit will not be equal to or less than the setting value specified in function setting
No. 35, minimum rotation speed, and also will not equal to or more than the setting value specified
in function setting No. 96, maximum rotation speed.
The command is executed without the delay time when the delay time is 0. Other than that, LSW is disabled
within the specified delay time, and LSW input is enabled after lapse of the delay time.
Thread trimming is executed.
The command is disabled when the delay time is 0. Other than that, the thread trimming command is provided
within the specified delay time.
Thread trimming output is delayed.
The command is executed without the delay time when the delay time is 0. Other than that, the thread trimming
delay command is provided within the specified delay time, and canceled after lapse of the delay time.
Up position stop is executed. Even if speed is specified by other command, the command is ignored.
The command is executed without the delay time when the delay time is 0. Other than that, the up position stop
command is enabled within the specified delay time, and disabled after laps of the delay time.
When the command is executed, positive rotation is performed to make the needle move to the up position if it
is at the down position or to make the needle move to the down position if it is at the up position. Even if speed
specified by other command, the command is ignored.
The command is executed without the delay time when the delay time is 0. Other than that, the command is
enabled within the specified delay time, and disable after lapse of the delay time.
Stop is executed by applying brake in a reverse rotation from the angle specified in function setting
No. 107, reversing brake start angle.
The command is executed without the delay time when the delay time is 0. Other than that, the command is
enable within the specified delay time, and disabled after laps of the delay time.
After lapse of the specified angle, transition to the next step is executed. When all the conditions for input are met
before lapse of the specified angle (AND input), transition to the skip destination step No. is executed. (A reference
angle is an angle from the point departing from the up position for a machine head using a belt and an angle from
the upper needle dead point for a direct motor type machine head.)
After lapse of the specified angle, transition to the next step is executed. When any one of the input conditions is met
before lapse of the specified angle (OR input), transition to the skip destination step No. is executed. (A reference
angle is an angle from the point departing from the up position for a machine head using a belt and an angle from
the upper needle dead point for a direct motor type machine head.)
Sewing machine stop is executed.
Transition to the next step is immediately executed when the delay time is 0. Other than that, transition to the next
step is executed after lapse of the specified time.
The reverse feed stitching switch is set to on/off.
The command is executed without the delay time when the delay time is 0. Other than that, the back tack output is
set to "on" within the specified time, and is set to "off" after lapse of the specified time.
The presser lifting switch command is set to on/off.
The command is executed without the delay time when the delay time is 0. Other than that, the presser lifting output
is set to "on" within the specified time, and is set to "off" after lapse of the specified time.
Initialization of the step of a specified program number is executed.
The step of a specified program is forcibly returned to the initial step.

Hide quick links: