No.
Description of error detected
E733
Inverse rotation of motor
E799
Predetermined time for thread trimming
sequence is exceeded
E808
Solenoid short circuit
E809
Holding motion failure
E810
Solenoid short-circuit
E811
Abnormal voltage
E906
Operation panel transmission failure
E924
Motor driver failure
E942
Faulty EEPROM
Cause of occurrence expected
• This error occurs when the motor is
running at 500 sti/min or more in the
opposite direction of that of rotation
indication during motor is running.
• Thread trimming sequence control is
not completed within the predetermined
time (three seconds).
• Solenoid power does not become
normal voltage.
• Solenoid is not changed over to
holding motion.
• When the short-circuited solenoid is desired
to be driven.
• When voltage higher than guaranteed
one is inputted.
• 200V has been inputted to SC-922 of
100V specifications.
• JA : 220V is applied to 120V box.
• CE : 400V is applied to 230V box.
• When voltage lower than guaranteed
one is inputted.
• 100V has been inputted to SC-922 of
200V specifications.
• JA : 120V is applied to 220V box.
• Inner circuit is broken by the applied
overvoltage.
• Disconnection of operation panel cord.
• Operation panel has broken.
• Motor driver has broken.
• Data cannot be written on the EEPROM. • Turn the power OFF.
– 74 –
Items to be checked
• Connection of the encoder of main shaft
motor is wrong.
• Connection for the electric power of main
shaft motor is wrong.
• Check whether the machine head actually
installed is different from the machine head
selection.
• Check whether the actual motor pulley
diameter is different from the motor pulley
setting (effective diameter).
• Check whether the belt has slackened.
• Check whether the machine head cord
is caught in the pulley cover or the like.
• Check whether the solenoid is abnormally
heated. (CTL circuit board asm. Circuit
is broken)
• Check whether the solenoid is short-
circuited.
• Check whether the applied power voltage
is higher than the rated voltage + (plus) 10%
or more.
• Check whether 100V/200V changeover
connector is improperly set.
In the aforementioned cases, POWER
p.c.b is broken.
• Check whether the voltage is lower than
the rated voltage - (minus) 10% or less.
• Check whether 100V/200V changeover
connector is improperly set.
• Check whether fuse or regenerative
resistance is broken.
• Check the operation panel connector
(CN38) for loose connection and
disconnection.
• Check whether the operation panel cord
has broken since the cord is caught in
the machine head.