Data Processor - Minolta CR-400 Instruction Manual

Chroma meter
Table of Contents

Advertisement

Specifications
<Data Processor>
Name
Model
Display range
Measurement time
Minimum measurement interval
Battery performance
Illuminants
Display
Tolerance judgment
Color space/colorimetric data
Languages
Storable data sets
Color difference target colors
Calibration channels
Page function
Display
Printer
Statistical function
Automatic measurement
Interface
Power source
Size
Weight
Operating environment
Storage environment
152

Data Processor

DP-400
Y: 0.01 to 160.00% (reflectance)
1 sec.
*
3 sec.
*
Approx. 800 measurements (when using batteries under company testing
Minolta's conditions)
C, D65
Chroma values, color difference values, color difference graphs,
PASS/WARN/FAIL display
Color difference tolerance (box tolerance and elliptical tolerance)
*
Only for the display function
XYZ, Y x y, L*a*b*, Hunter Lab, L*:C*h, Munsell (only illuminant C), CMC
*
(l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI-Tw (only illuminant D65),
WI ASTM E313 (only illuminant C), YI ASTM D1925 (only illuminant C),
YI ASTM E313 (only illuminant C), User index (up to six registered in the
Measuring Head can be used)
Operating keys: English
LCD : English (default), German, French, Italian, Spanish, Japanese
Max. 2000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are
possible
Only for the operating function (100 pieces of data when the measuring head
*
is connected; input of measurement values or numeric)
(independent of page function)
Only for the operating function (20 channels when the measuring head is con-
*
nected) (ch00: white calibration; ch01 to ch19: user calibration)
100 pages
Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display)
Contrast adjustment
384 dot line thermal printer (can also print graphs)
Automatically prints out all measurement results (can be set not to)
Maximum, minimum, average, and standard deviation
Date and time display: year, month, day, hour, minute
*
Timer: 3sec. to 99 min. (Some measurement modes require more than 3 sec.)
RS-232C compliant
Baud rate (bps): 19200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the
measurement head
4 AA size alkali or Ni-MH batteries
AC adapter (AC-A17) AC120V
50-60Hz 0.4A (for worldwide except N.America)
100(W) x 73(H) x 255(D)mm
Approx. 600g (not including batteries and paper)
Temperature: 0 to 40°C, Relative humidity: max. 85%, No condensation,
Altitude: 2000m or lower (indoor), Installation category: II, Pollution degree: 2
Temperature: -20 to 40°C, Relative humidity: max. 85%, No condensation
50-60Hz 0.4A (for N.America) AC230V