Fault finding

Symptom
Probe fails to power up
(no LED illuminated, or
fails to indicate current
probe settings)
Probe fails to switch-on
Probe switches-on
unexpectedly
www.armata-cnc.ru
Cause
Dead batteries
Wrong batteries
Batteries inserted incorrectly
Wrong optical start configuration
selected
Dead batteries
Wrong batteries
Batteries inserted incorrectly
Optical/magnetic interference
Transmission beam obstructed
Probe out of range/not aligned
with receiver
No receiver start signal
Probe receiving switch-on
signal from receiver on adjacent
machine
info@armata-cnc.ru
Action
Change batteries
Change batteries
Check battery insertion
Reconfigure
Change batteries
Change batteries
Check battery insertion
Check for interfering lights or
motors
Consider removing interfering
source
Check that probe and receiver
windows are clean, and remove
any obstruction
Check alignment and if receiver
fixing is secure
Refer to relevant user's guide
Review installation wiring
Reduce switch-on range on
receiver on adjacent machine