Ots Performance Envelope With An Omi-2T/Omi-2/Omi-2H - Renishaw OTS Installation Manual

Optical tool setter
Hide thumbs Also See for OTS:
Table of Contents

Advertisement

OTS installation guide
OTS performance envelope with
an OMI-2T/OMI-2/OMI-2H
(modulated transmission)
NOTE:
3.2
A single OTS configured to Probe 1
can be used with an OMI-2
75°
5 (16.4)
4 (13.1)
3 (9.8)
OTS
Optical power setting
If two machines are operating in close proximity
to each other, take care to ensure that signals
transmitted from a probe on one machine are not
received by the receiver on the other machine,
and vice versa.
When this is the case, it is recommended that the
low optical power setting on probes is used, and
that the low range setting is used on the receiver.
30°
45°
15°
60°
2 (6.5)
1 (3.3)
www.armata-cnc.ru
O
MI-2T/OMI-2/OMI-2H
75°
60°
45°
30°
15°
15°
15°
30°
45°
60°
75°
Receiver position
To assist finding the optimum position for the
installation, signal condition is displayed on the
OMI-2T/OMI-2/OMI-2H receiver.
Please refer to the receiver User's Guide.
info@armata-cnc.ru
+7(495)797-78-97
1 (3.3)
2 (6.5)
3 (9.8)
4 (13.1)
5 (16.4)
75°
60°
45°
30°
Typical plot at 20° C (68° F)
Range m (ft)
Switch on/off
Operating - standard power mode
Operating - low power mode