6.2 CLAMPING CABLES AND SHIELDING
CABLES
Of the cables connected to the YASNAC, clamp those that need
(a) Strip part of the cable shield as shown in the figure below to
shielding to the ground plate securely with the cable clamping
expose the shield enclosure.
fixtures as shown in the figure below. This clamping serves not
Press the exposed part onto the ground plate using the cable
only as cable support but also as cable shielding.
In ensuring safe
clamp.
operation of the system, it is extremely important that you clamp
(b) Mount the ground plate near the cable opening.
the necessary cables without fail.
(c) Stripping cable enclosure is not required for non-shielded cables
for clamping.
CABLE
SHIELD
ENCLOSURE
ABLE CLAMP
TYPE 1
TYPE 2
DF8401485
DF8404817
19.5
-=3252 s2--
'CABLE
Fig. 6.2 Shielding Cables