YASKAWA YASNAC J50 Connecting Manual page 163

Yasnac j50 series
Table of Contents

Advertisement

20.2.46
S4-DIGIT COMMAND
EXTERNAL
OUTPUTS
(SB1 THROUGH
SB16) AND S5-DIGIT
COMMAND
EXTERNAL
OUTPUTS
(SDA1 THROUGH
SDA16 OR
SDI1 THROUGH SD116)
These inputs and outputs are used, when the control is of S5-digit
analog output or non-contact
output to output the results of the
operation by the S command in the part program to the outside and
perform the actual S5-digit command 12-bit non-contact output or
analog output according to the inputs from the outside.
(1) S5-Digit Command 12-Bit Non-Contact Output
Output of operation
results to outside:
SBL through
SB 12
(2) S5-Digit Command Analog Output
(a) Output of operation results to outside: SDA1 through SDA16.
Note: The input/output value is signed binary 16-bit.
The relationship with analog voltage is as follows.
-32768 to O to +32767
1
I
-1OV to Ov to +Iov
I
(b) Input from outside for outputting
analog voltage to DAS.
SGSO: SDI1 through SDI16.
The primary purpose of this function is to control the S5-digit
analog output command or non-contact
output command by the
sequencer built in the control. This function should not be used for
other purposes unless specifically required.
Operation results are
output selectively
to the outside directly by NC or via outside
inputs, depending
on the setting of parameter
#6032, D2.
Set
#6032, D2 to" 1" tp output via outside inputs.
20.2.47
EXTERNAL
INPUT, VERIFY
AND OUTPUT
SIGNALS (EIN, EVER, EOUT, ECLM, IER, EDTS)
These signals are to command input, verification, and output of part
programs to the part program memory by means of external signals.
•1
# 13182
I
04
EOUT
_
EXTERNAL
OUTPUT
Z=I==-:EAL
&
# 12236
'
EDTS
EDIT CONDITION
COM
Fig. 20.28
(1) External Input (EIN) Input
If the EIN input is closed in label-skip state in the EDIT mode, the
function will automatically
switch to PROG.
And it will start to
store the part program in the part program memory through the
input device (or interface) specified by parameter #6003. Set up the
part program to be stored in the following format.
Registration of the program will be executed with the program
number (O number) specified at the beginning of the part program.
Program storage ends when the NC reads the EOR code (ER or %)
at the end of the program.
Notes :
1. If O number has already been registered, store the program after
erasing the existing program wiht the external memory clear
(ECLM) input (see (4) this paragraph).
2.
If parameter #6021 D6= 1, execute storage after erasing the
dupIicate O number.
PROGRAM
NUMBER
< EIA
CODE
>
r(INDIVIDUAL
BLOCK
COMMAND)
,
1
-
ER
CR
[0
PROGRAM
NO*
PART
PROGRAM—
M30
CR
ER
T
T
I
4
+
< ISO COD'E > ~
I
=
~
LF/NL
(0 pROGRA~
-F==?
PART
PROGRAM—
M30
:.
I
GENERALLY
CALLED
" EOB
CODE"
,
OR "END
OF BLOCK
CODE"
: . . . ..
J--. (OR
M13,2)
I
~ . _ _ -GENERALLY
CALLED
'lEOR
CODE1l
OR
"REWIND
STOP
CODE"
Fig. 20.29