9. The motor is decelerated with the deceleration ramp and the inverter is stopped untill the
temperature doesn't fall below the limit value. If the AUTORESET function is activated (see
TAB3, SUB XPAR, function SW3), a reset is possible by setting or the START/STOP in-
put, or the E ABLE input, or by setting the setpoint to zero.
10. Behaviour with Softw. D2A-STD: see 4) Behaviour with Softw. D2A-1300: see 2)

13.3.7 Hardware error messages

An error which is established during the self-test phase or during operation is shown on the display
by the message ''ERROR'' together with an error number. The inverter is stopped by the safety de-
vices.
To reset the error message, switch off the mains supply and switch back on again. If the error is not
rectified by this, send the unit to the after-sales service for inspection.
E
RROR
ERROR 1
Data error
ERROR 2
Hard- and software is not compatible
ERROR 3
CPU error
ERROR 4
Keypad error
ERROR 5
Error in ROM
ERROR 6
Watchdog error
ERROR 7
Clock error
ERROR 8
Program error
ERROR 9
Output stage error
Instruction & Parts Manual
C
AUSE
REMEDY
Reprogram parameters.
Have unit checked by technical af-
ter-sales service.
Pag.40
Edition 2008-A