13.3.2 Display

An eight-position alphanumeric display provides the user with all important information, such as
inverter status messages and information on possible errors or faults and parameter setting
values.The language for the display readout is selectable.

13.3.3 Help - function and language - selection

When pressing SHIFT and INC, on the display appears a scrolling Help-text concerning the current-
ly active function. Releasing INC and pressing DEC while holding SHIFT inverts the text scroll -
direction. Pressing SHIFT and INC in TAB1, funct. 1 enters the language - select mode. Select the
language by pressing the corresponding key.
Italian
German
English
The selected language will be saved automatically. Press any key to return to TAB1, funct. 1.

13.3.4 Inverter status

M
ESSAGE
OFF
STOP
1 33.6Hz
JOG
DEFAULT
SECUR. 1
Instruction & Parts Manual
a) Jump back to the first function of the function table or sub-menu.
b) Jump out of the table or sub-menu (starting from the first function of
the function table or sub-menu).
Increments the parameter value of the selected function.
To increase the speed at which scrolling through the value range takes
place, keep I C depressed and briefly press DEC.
Reduces the parameter value of the selected function.
To increase the speed at which scrolling through the value range takes
place, keep DEC depressed and briefly press I C.
Permits access to a sub-menu or a parameter table.
Help function: A Help text can be called for each function. A key chan-
gefrom I C to DEC with depressed SHIFT key inverts the text scroll-
direction of the help text.
Software reset.
SELECT
I C
DEC
No E ABLE, terminals 10/11 open.
If the AUTOSTART function is deactivated, the inverter is stopped af-
ter switching on (see TAB3, SUB XPAR, function SW7 = OFF). Acti-
vate E ABLE or START/STOP to start the inverter.
Display of current actual values or changeable parameters (the first
number group indicates the function number and the 2nd number group
the value of the respective parameter).
JOG mode is activated; output frequency setting by means of the unit
keypad.
Default parameter values (works setting) have been loaded but not
saved.
SECURITY Level 1 is activated; parameter values cannot be saved.
D
ESCRIPTIO
Pag.38
Edition 2008-A

Advertisement