11. SAFETY DEVICES

11.1 L
IMIT SWITCHES A D SEG ALATIO DEVICES

11.1.1. Limit switches

On the machine there are the following limit switches
D
ESIGNATION
FC0
FC1
FC5, FC6
FC7
FC8
FC9
FC11
11.1.2. Speed reducer
Not necessary
11.1.3. Mechanical extra stroke
The following extra stroke mechanical protections are mounted:
• Head down;
• Index forward.
11.1.4. Signals
See 12.1.2
11.1.5. Led, indicators and signals to avoid danger situations
Information about emergencies and dangerous situation concerning machine normal operations are showed by control dis-
play.
A red light in the electrical cabinet indicates that electrics are switched ON.
11.1.6. Protection devices
The blade is protected, where uncovered, by two guides that reduce the risk, but that cannot completely cover it.
11.2. F
IX PROTECTIO S
The moveable parts of the machine are protected by fix covers, which can be removed using tools.
11.3. M
OVEABLE PROTECTIO S
The wheels are covered by two removable doors which can be opened to inspect or replace the blade. Two safety interlock
switches automatically stop the machine if the cover is opened while the machine is working.
11.4. S
AFETY FEATURES SET
The limit switches are set up at the factory.
Instruction & Parts Manual
Home position
Out of stock
Safety band wheel door interlock switches
Head down
Head up (option)
Blade broken
Head fast approach – Magic want
-
UP
D
ESCRIPTION
Pag.23