Scanner Interface
Control register B#0
MSB
7
6
5
0
0
0
(b)
Control register A#1
Control register B#1
X'00' is set when the power is turned on or when a CLEAR command is issued for initialization.
MSB
7
6
5
0
*1
The scanning speed of ADF (sheets/min) in Linedrawing mode is different from that of Photograph
mode. See Appendix C for more information.
Appendix A-24
LSB
4
3
2
1
0
0
0
0
0
0
LSB
4
3
2
1
0
Density
Linedrawing/photograph
00XXX: Set from the operator panel
0 1 0 0 0:
Light
0 1 0 0 1:
0 1 0 1 0:
Somewhat light
0 1 0 1 1:
0 1 1 0 0:
Normal
0 1 1 0 1:
0 1 1 1 0:
Somewhat dark
0 1 1 1 1:
Dark
1XXXX:
Automatic (*2)
0X:
Specified from the operator panel
1 0:
Linedrawing (*1)
1 1:
Photograph (*1)
Darken more
and more
(*3)

Advertisement