Interface deference between M3097DE and M3093DE
B.3 Control register A#0
The selection of the output resolution, Flatbet/ADF sellection, and the way to start can be set by the
operator panel of M3097DE as follows.
Control register A#0
7
6
5
4
0
The way to set start of reading
0 :
1 :
*1 If the scanner is M3093DE without memory option, the scanning area may be
(See Table 2.5)
Maximum main scanning dots
Maxi,um sub-scanning lines
*2 If 600dpi is specified for M3093DE, you can not set "Automatic" in density
Appendix B-2
3
2
1
0
Flatbed/ADF
M3097DE
0 × :
Set from the operator panel
1 0 :
Flatbed operation
1 1 :
ADF operation
M3097DE
Set from the operator panel
Set from Host computer
limited as follows.
specification of control register A#1/B#1.
Output resolution
M3097DE
0 × × ×
Set from the operator
:
panel
1 0 0 0 :
400 dpi
1 0 0 1 :
300 dpi
1 0 1 0 :
240 dpi
1 0 1 1 :
200 dpi
1 1 0 0 :
100 dpi
1 1 0 1 :
150 dpi
1 1 1 0 :
Not defined
1 1 1 1 :
600 dpi *1 *2
M3093DE
No operation
M3093DE without memory option
3456 pixels
5600 pixels
M3093DE
No operation
M3093DE
No operation

Advertisement