Download Print this page

OEM M3097DE Manual page 96

Image scanner

Advertisement

(a)
Control register A#0
X'00'is set when the power is turned on or when a CLEAR command is issued for initialization.
MSB
7
6
5
0
*1
When the start of reading is specified from the operator panel, the Ready lamp lights at reception of a
START command.
LSB
4
3
2
1
0
Scanning resolution
0XXX:
Set from the operator panel
No operation (Other scanners)
1 0 0 0
400 dpi
1 0 0 1
300 dpi
1 0 1 0
240 dpi
1 0 1 1
200 dpi
1 1 0 0
100 dpi
1 1 0 1
150 dpi
1 1 1 0
Not defined
1 1 1 1
600 dpi
Flatbed/ADF
0X:
Set from the operator panel
1 0:
Flatbed operation
1 1:
ADF operation
Specified start of reading)
0:
Operator panel (*1)
1:
Host computer
A.3 Commands and Response
Appendix A-23

Advertisement

loading