o:
Can be specified.
x:
Cannot be specified.
:
Enabled if automatic separation is specified, otherwise ignored.
:
Can be specified but not enabled.
*1 If DTC is specified, IPC can be specified but not enabled.
*2 The image is not guaranteed.
*3 Can be specified but not enabled if Image Emphasis is also specified.
*4 Can be specified but not enabled if Outline Extraction is also specified.
3.2

Basic image functions

The command and register name in [ ] beneath the section title shows where the item is specified in
Appendix A.
3.2.1

Output resolution

[A.3.3.2 CONTROL command / Control register A#0]
Selectable output resolution is shown in Table 2.3. The default is 400 dpi.
The output resolutions of 100/150/200/240/300/600 dpi are converted from 400dpi by an electrical
method. If IPC option is installed, Zooming function is available (see section 3.3.4). The output
resolution with IPC option is shown in Table 2.4.
3.2.2

Main Window area

There are four ways to specify the Main Window , that is;
(1)
Specification by the operator panel or ADF paper size detection
(2)
Specification by standard document size
(3)
Specification by width and length
(4)
Specification by offset, width and length (Clipping)
Top three methods, (1) to (3), are the methods which specify both front side and back side at a time.
And the method (4) are available to set deferent area for front side and back side.
User must count in the mechanical offset error of the scanner as shown in Table 3.1. User can adjust
the offset with Setup mode of operator panel, scanner by scanner.