5.1.5

Function of CE mode

CE mode is available only for maintenance person, so the details of the CE mode are shown in the
maintenance manual of this scanner. In this section only the items of the CE mode is shown in table
5.4 as a reference.
Table 5.4 Function of CE mode
LCD display
T01 Single Test feed
T02 Multi Test feed
T03 Offset Adjsutment
T04 EEPROM Setting
T05 OP Panel Test
T06 ADF Sensor Test
T07 PROM Version
T08 Life Counter
T09 Baud Rate
T10 Product ID
T11 Memory Test
5-8
Features
Scanner tests the FB or ADF single sheet reading.
Scanner tests not only the feeding but also AGC control of
carrier unit and Optical unit.
Scanner continuously tests the feeding and AGC control
unit "Exit" is pressed.
Scanner automatically adjusts the offset of FB image,
ADF front image and ADF back image.
This function supports the inquiry and over-writing of the
EEPROM data.
Scanner tests the function of the LCD, LEDs and switches
on the operator panel.
Scanner tests the switches on ADF indicating the ON/OFF
real time status on LCD.
Scanner displays the firmware version in PROM.
Scanner displays the accumulated sheet number wich ADF
has fed.
This function supports the baud rate setting of RS232C.
Baud rate is selectable from 9600/4800/2400/1200 bps.
This function supports the setting of Product ID of SCSI
interface.
Product ID is selectable from
M3099G/M3097DG/M3097G/M3093DG/M3093GX/
M3096G/M3096GX.
Scanner tests the image memory.