Scanner Interface
A.3.3.9 IMAGE MODE SENSE command
This command is valid for the scanner with the image processing circuit. When the scanner
receives this command, the scanner reports the image processing mode of the mainwindow and the
number of pixels (Unit: Byte) per line in the X-direction.
By specification byte 3 of this command, the front or back-side image status can be selected.
Byte 1
CNT
X'03'
A.3.3.10
SEND DITHER 1 command
This command is valid for the scanner with the image processing circuit. By this command,
download patterns of dither or overlay pattern can be registered.
Byte 1
CNT
X'43'
Appendix A-68
Byte 2
CMD
X'00':
Front side image status is required.
X'43'
X'40'
Back side image status is required.
Byte 2
Byte 3
TEXT
CMD
Dither or overlay pattern
X'46'
number
Byte 3 TEXT
Byte 4 or later
Pattern data to be
registered