Image scanner

Advertisement

(p)
Extended control register #3
7
6
5
4
#3
0
0
0
0
X'00' must be set to this register.
X'00' is set when the power is turned on or CLEAR command is issued for initialization.
A.3.3.3 IMAGE CONTROL command
This command sets the scanner to the operation mode of the image processing circuit.
Byte 1
Byte 2
CNT
CMD
X'0x'
X'5A'
7
6
Third byte
0
Note:
If this command is sent to the scanner without image processing option (IPC-2D or IPC-3D), the scanner
sends "Operation error" as response.
LSB
3
2
1
0
0
0
0
0
Byte 3
TEXT
Image control
register start
number.
LSB
5
4
3
2
1
Image control register selection
0: Selects image control register A (front side)
1: Selects image control register B (back side)
Byte 4
or later
Image control
register
0
Image control register start number.