A.3.3.1 CLEAR command
This command initializes the scanner and can be issued at any time.
Byte 1
Byte 2
CNT
CMD
X'03'
X'44'
CLEAR command details
7
6
5
4
3
Note: "Ready" is the response when this command ends normally.
*1
If the CONTROL REGISTER CLEAR command is issued after the READ command is sent to the scanner
but before the Read Complete is received from the scanner, a command sequence error occur.
Byte 3
TEXT
Details on CLEAR command
LSB
2
1
0
00: Power-on clear
This command resets the system to the
power-on status.
01: Control register clear
This command initializes the operation
mode, image processing mode, and
subwindow mode. (*1)
10: Reading stop
This command stops operation during
reading (VGATE OFF, return).