Scanner Interface
(n)
Extended control register #1
7
6
5
#1
0
0
0
Note: X'00' must be set to this register.
X'00' is set when the power is turned on or CLEAR command is issued for initialization.
(o)
Extended control register #2
7
6
5
#2
This register specifys the transfer rate of binary reading for front-side and back-side image data.
X'00' is set when the power is turned on or CLEAR command is issued for initialization.
*1 :
When the output resolution is 400 dpi or less, transfer rate is 800 ns.
When the output resolution is 401 dpi or more, transfer rate is 400 ns.
*2 :
This is available only for third party slot. It is necessary to check the operation with the Host computer.
Appendix A-40
LSB
4
3
2
1
0
0
0
0
0
0
LSB
4
3
2
1
0
0
0
0
0
Front-side data transfer rate
0XXX:
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
Back-side data transfer rate
0XXX:
1 0 0 0: Undefined
1 0 0 1: 800 ns
1 0 1 0: 400 ns
1 0 1 1: 200 ns *2
1 1 0 0: Undefined
1 1 0 1: Undefined
1 1 1 0: Undefined
1 1 1 1: Undefined
Reserved
Depending on the resolution (*1)
: Undefined
: Undefined
: Undefined
: Undefined
: Undefined
: Undefined
: Undefined
: Undefined
Two fold speed: 400 ns