B.4 Control register A#1
Control register B#1
Control register A#1 / B#1
7
6
5
4
0
B.5 Control register A#2
Control register B#2
Halftone can be specified the operator panel of M3097 as follows.
Control register A#2 / B#2
7
6
5
4
Built-in/Download of dither pattern selection
3
2
1
0
Density
0 0 × × × :
0 1 0 0 0 :
0 1 0 0 1 :
0 1 0 1 0 :
0 1 0 1 1 :
0 1 1 0 0 :
0 1 1 0 1 :
0 1 1 1 0 :
0 1 1 1 1 :
1 × × × × :
Linedrawing/Photograph
M3097DE
00 :
Set from the operator panel
10 :
Linedrawing
11 :
Photograph
*1 This function is valid for image processing circuit (IPC-2/3 or IPC-
2D/3D) option. When the IPC-2/3 or IPC-2D/3D option is installed and
these bits indicate 1XXXX, the scanner applies the DC function , and
the function of the image control register and sub-window control
register are not operated.
3
2
1
0
Jam detection when scanning
Binary/Grayscale selention
Specifies halftone
M3097DE
00 :
Set from the operator panel
10 :
Not dithered
11 :
Dithered or Error Diffusion
Density setting
M3097DE
Set from the operator panel
Light
Somewhat light
Normal
Somewhat dark
Dark
Automatic *1
M3093DE
No operation
B.4 Control register A#1
M3093DE
No operation
M3093DE