Connection Of A Braking Resistor With Simple Temperature Monitoring; Connection Of A Braking Resistor With Extended Temperature Monitoring - KEB combiverty Instruction Manual

Accessory
Table of Contents

Advertisement

Available languages

Available languages

Braking Resistors
1.10

Connection of a braking resistor with simple temperature monitoring

This connection causes malfunctions. A short circuit in the braking transistor is recognized,
but it does not lead to the disconnection of the mains voltage. This connection cannot be used
without external measures, if increased fire protection is required.
1.11

Connection of a braking resistor with extended temperature monitoring

Protection in case of defective braking transistor is only available with switching off the mains
voltage. This connection must be used if increased fire protection is required.
+24V
GND
K1 Line contactor with auxiliary contacts
S1 Pushbutton or contact of superior control for
switching on
S2 Emergency stop switch or contact of superior
control for switching off
H1 Control of the tripping or signal for evaluation
electronics
G1 Frequency inverter
GB - 10
S2
FL
FR
OH1
OH2
12
K1
S1
11
K1
PA
PB
OH1
OH2
��
��
��
K1
H1
M
Motor
FL
Temperature switch of further monitoring objects
(e.g. choke)
fr
Temperature switch of braking resistor
R
Braking resistor
L1
L2
L3
+PA
- -
PB
U
V
W
T1
T2
1
3
5
R
2
4
6
+PA
PB
L1 L2
L3
G1
U
V W
M
13
K1
14
T1 T2

Advertisement

Chapters

Table of Contents
loading

Table of Contents