KEB combiverty Instruction Manual page 16

Accessory
Table of Contents

Advertisement

Available languages

Available languages

Braking Resistors
Part number
22.BR.226-6866
23.BR.226-6676
24.BR.226-6506
25.BR.226-6436
26.BR.226-6386
27.BR.226-6336
28.BR.226-6226
29.BR.226-6176
30.BR.226-6136
PD
ps
cdf
The calculated peak braking power must be smaller than the maximum load capacity of the
resistance. Please contact KEB if the value is not reached.
Opening temperature of the installed thermojunctions
Part number
xx.BR.100-xxxx
xx.BR.110-xxxx
xx.BR.226-xxxx
GB - 6
Number
R
P
of
modules
[W]
1
8,6
4000
1
6,7
5200
2
5
6900
2
4,3
8100
2
3,8
9200
2
3,3
10000
3
2,2
15000
4
1,7
20000
5
1,3
26000
Continuous power
Peak load, max. for specified ON period
Cyclic duration factor
recommended core cross- section per module
P
cdf
D
S
[kW]
[s]
[AWG] / [mm²]
68
6
2 x 6 / 2 x 16
86
6
2 x 6 / 2 x 16
115
6
2 x 6 / 2 x 16
135
6
2 x 6 / 2 x 16
154
6
2 x 6 / 2 x 16
173
6
2 x 6 / 2 x 16
260
6
2 x 6 / 2 x 16
340
6
2 x 6 / 2 x 16
440
6
2 x 6 / 2 x 16
Opening temperature
160 °C
160 °C
240 °C
Terminals
Core cross-
section
[AWG] / [mm²]
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16
2 x 6 / 2 x 16

Advertisement