Dr 6 Limits - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions of the belt scale

8.8 DR 6 Limits

8.8
DR 6 Limits
Various limits are parameterized in data record DR 6. The factory-set parameters
correspond to the typical settings.
Procedure
● Read the current parameters from the SIWAREX module (receive)
● Check all parameters and modify them as required
● Transfer the data record to the SIWAREX module (send)
Table 8- 4
Assignment of data record 6
Variable
Data record number
Length
Application
Version identifier
Negative and positive
zero offset in %
(Page 94)
Smallest totalized
value (Page 94)
Minimum flow rate
(Page 94)
Maximum flow rate
(Page 94)
Delay for flow rate
limits (Page 94)
Minimum belt speed
(Page 94)
Maximum belt speed
(Page 94)
Delay for belt speed
limits (Page 95)
Minimum belt load
(Page 95)
92
Note
Contains no. of data record
Data record length information
Information about which
application the DR belongs to
Information about current data
record version
Negative range of zero adjuster
referred to the originally
calibrated zero point.
Specification in % of maximum
belt load
Positive range of zero adjuster
referred to the originally
calibrated zero point.
Specification in % of maximum
belt load
Smallest totalized value which
may be recorded with verification
capability
Min. flow rate in % of design flow
rate (for status display)
Max. flow rate in % of design flow
rate (for status display)
Delay for output of status display
for flow rate (in ms)
Min. belt speed for status display
'Minimum belt speed violated' in
% of design speed
Max. belt speed for status display
'Maximum belt speed violated' in
% of design speed
Delay for output of status display
for belt speed (in ms)
Min. belt load for status display
'Minimum belt load violated' in %
of nominal belt load
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
LONG
4
rw
FLOAT
4
rw
FLOAT
4
rw
LONG
4
rw
FLOAT
4
rw
Default
Min.
Max.
6
-
-
90
-
-
104
-
-
1
1
65635
1
0
100
3
0
100
0
0
0
0
200
100
0
200
1
0
10
0
100
100
0
200
1
0
5
0
100
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Register
1264
1265
1266
1267
1268
1270
1272
1274
1276
1278
1280
1282
1284
1286

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents