Technology Error Message List; Data And Operating Errors Message List - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

Messages
9.5 Message list
9.5.2

Technology error message list

Technology error (code 2000 to 4999)
2000 Technology error
2002 Trace error
2003 Zeroing aborted
2004 Trace memory full
3001 Totalizer error
3002 Calibration procedure interrupted
9.5.3

Data and operating errors message list

Data and operating errors
(code 5000 to 8999)
5000 Data and operating error exists
5001 Command code or data record
unknown
5002 Command or data change not
possible because write protection is active
5003 Cannot exit service mode
5004 Command or data transmission only
available in service mode
5006 Command or data transmission not
possible because of BUSY
5007 Command or data transmission not
possible because module is faulty or
SIMATIC CPU stop
5104 Command not possible because
range is exceeded
5105 Load cell parameters not plausible
5108 ID does not exist
5199 Error in command to DI
6002 Logging not possible because weight
is too small
6003 Command cannot be executed since
a dynamic procedure is already active
142
Error code
Description and remedy
2000
Group message, at least one technology error exists
2002
The set recording rate for trace function cannot be processed. Set
a slower recording rate.
2003
The zeroing procedure has been canceled. Possible causes:
violation of zeroing limits.
2004
The trace recording has been cancelled. Possible causes: trace
memory full and not declared as ring memory.
3001
Fault occurred during totalizing.
3002
Current calibration procedure has been aborted. Possible causes:
non-plausible values have been determined during the command.
Error code
Description and remedy
5000
Group error, a bit is set in the data and operating error bits
5001
Command code or data record is not known with current
application
5002
The command or changing of data is not possible due to write
protection. The data record was rejected.
5003
Cannot exit calibration mode; calibration incomplete
5004
Activation of service mode is required to execute command or
transmit data
5006
Command can currently not be executed because module is
BUSY (data record or command transmission already active,
...)
5007
Command can currently not be executed because of a
problem or SIMATIC CPU stop
5104
Command (e.g. set to zero, tare, calibrate command) cannot
be executed because the permitted range has been
exceeded. The ranges are defined in DR 3.
5105
Load cell parameters in data record DR 10 are not plausible
(number, support points, load specifications, etc.).
5108
Requested logbook ID not present in memory.
5199
Processing of a command triggered at the DIs is not possible.
The cause can be determined in data record DR 32.
6002
Logging is not possible because the limits for the minimum
weight or maximum weight were not observed.
6003
Desired command cannot be executed since a dynamic
command (calibration, zeroing) is already being executed.
SIWAREX WP241
Manual, 04/2014, A5E33713528A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents