Scale parameters and functions of the belt scale
8.12 DR 10 load cell parameters
8.12.1
Number of load cells
The number of load cells is required for automatic calibration.
8.12.2
50/60 Hz toggling
To improve the suppression of faults caused by the supply network, you can specify the
network frequency for signal filtering.
8.12.3
Load cell characteristic value
The characteristic value of the load cell(s) is required to correctly interpret the output voltage
from the load cell. The exact value can be entered if the measurement log for the load cell is
available. The mean value of all characteristic values is used if there is more than one load
cell.
Example
Characteristic value = 2.018 mV/V
8.12.4
Rated load of a load cell
The rated load of a load cell is required for checking the maximum weighing range of the
scales. The rated load is entered in the specified units of weight.