Technical specifications

12.1
Technical specifications
24 V power supply
Note
A protective extra-low voltage (to EN 60204-1) is to be ensured by system power supply.
Table 12- 1
Rated voltage
Static low / high limits
Dynamic low / high limits
Non-periodic overvoltages
Maximum current consumption
Typical power loss of the module
Power supply from SIMATIC S7 backplane bus
Table 12- 2
Current consumption from S7-1200 backplane
bus
Analog load cell interface connection
Table 12- 3
Error limit to DIN1319-1 at 20 °C +10 K
Accuracy according to OIML R76
Accuracy delivery state
Sampling rate
Input signal resolution
Measuring range
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Technical specifications: 24 V power supply
Technical specifications: Power supply from SIMATIC S7 backplane bus
Technical specifications: Analog load cell interface connection
2)
24 V DC
19.2 V DC / 28.8 V DC
18.5 V DC / 30.2 V DC
35 V DC for 500 ms with a recovery time of 50 s
200 mA with 24 V DC
4.5 W
Typically 3 mA
≤ 0.05% v.E.
III and IV
Class
3000d
Resolution
(d=e)
0.4
Error
percentage pi
0.5 µV/e
Step voltage
typ. 0.1% v.E.
100 Hz
± 4 000 000
± 4 mV/V
12
1)