Dr 17 Control Analog Output; Analog Output Specification - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions of the belt scale

8.17 DR 17 Control analog output

8.17
DR 17 Control analog output
If data record DR 17 is configured as the source for the analog output (see Analog output
source (Page 102)), specifying a control output sends a corresponding output current at the
analog output.
Procedure
● In data record DR 7, check that "Control by DR17" has been configured as the source for
the analog output
● Check the analog output configuration (see Analog output source (Page 102))
● Enter a value in data record DR 17
● Transfer the data record to the scale
Table 8- 15
Assignment of data record 17
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application
the data record belongs to
Version
Information about current data record
identifier
version
Analog output
Value which is to be output (only
specification
relevant if source is "External
(Page 116)
specification", see DR 7)
Reserve 1
Reserve
Reserve 2
Reserve
8.17.1

Analog output specification

The value to be entered must be between the start value (Page 102) and the end value
(Page 103) of the analog output.
116
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
FLOAT
4
rw
SHORT
2
rw
USHORT
2
rw
Default
Min.
Max.
17
-
-
16
-
-
104
-
-
1
1
65635
0
-
-
0
0
-
0
0
-
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Register
1588
1589
1590
1591
1592
1594
1595

Hide quick links: