Dr 48 Date And Time 2 - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

8.28

DR 48 Date and time 2

The SIWAREX module has its own hardware clock. You can set and read the current date
and time using data record DR 48. The clock is buffered with a capacitor and continues to
operate for up to approximately 70 hours without a supply voltage. If you are not using the
Modbus protocol, data record DR 8 is used for the date and time.
Procedure
● Set the date and time
● Transfer the data record to the SIWAREX module
Table 8- 26
Assignment of data record 48
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identifier Information about current data record
version
Year
Year
Month
Month
Day
Day in month
Hour
Hour
Minute
Minute
Second
Second
Millisecond
Millisecond
Day of the week
Day of the week
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Scale parameters and functions of the belt scale
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
8.28 DR 48 Date and time 2
Default Min.
Max.
48
-
-
24
-
-
104
-
-
1
1
65635
2012
2012
2010
1
1
12
1
1
31
0
0
23
0
0
59
0
0
59
0
0
999
1
1
7
Register
6960
6961
6962
6963
6964
6965
6966
6967
6968
6969
6970
6971
137