Performance; Mechanical Data; Electrical Data; Lubrication Data - Edwards EH500 Instruction Manual

Hide thumbs Also See for EH500:
Table of Contents

Advertisement

A301-51-880 Issue T
For EH mechanical booster/CPH dry pump combination depending on the temperature class of the system:
Table 6 - CPH dry pump and EH mechanical booster pump combinations for T160
Dry Pump
Booster Pump
CPH 250
CPH 400
50 Hz
60 Hz
50 Hz
60 Hz
EH1200 T160

*

*
EH2600 T160

*

*
EH4200 T160
*
*

*
 Do not require extra protection
*
Consult Edwards for advice
Table 7 - CPH dry pump and EH mechanical booster pump combinations for T3
Dry Pump
Booster Pump
CPH 250
CPH 400
50 Hz
60 Hz
50 Hz
60 Hz
EH1200 T3




EH2600 T3




EH4200 T3
*
*


 Do not require extra protection
*
Consult Edwards for advice
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A301-51-880 Issue T
2.5

Electrical data

Note:
The motors of EH250, EH500 and EH500IND pumps are supplied configured for 'low voltage' operation (230 V
and lower), the motors of all other pumps are supplied configured for 'high voltage' operation (380 V and
higher): refer to
Section
3.6.
Table 10 - Electrical data
Electrical supply voltage
220/240/380/415 V, 50 Hz or 208/230/460 V, 60 Hz
Number of phases
3
Voltage tolerance:
50 Hz electrical supply
± 10%
60 Hz electrical supply
-2.5%, +5%
Full load current ratings
See below and refer to motor rating plate
220 V
240 V
380 V
415 V
208 V
230 V
Pump(s)
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
60 Hz
EH250
Full load (A)
6.3
5.8
3.7
3.4
6.1
5.5
EH500
Rating (kW)
1.5
1.5
1.5
1.5
1.5
1.5
EH250IND
Full load (A)
7.8
7.4
4.5
4.3
9.7
8.8
EH500IND
Rating (kW)
2.2
2.2
2.2
2.2
2.2
2.2
EH1200
Full load (A)
11.1
10.2
6.4
5.9
11.9
10.7
EH1200IND
Rating (kW)
3.0
3.0
3.0
3.0
3.0
3.0
EH1200C
Full load (A)
-
-
-
-
-
-
Rating (kW)
-
-
-
-
-
-
EH1200 T3/T160/
Full load (A)
10.4
9.9
6.0
5.7
-
-
T4X
Rating (kW)
3.0
3.0
3.0
3.0
-
-
EH2600
Full load (A)
19.8
18.2
11.5
10.5
20.9
18.9
Rating (kW)
7.5
7.5
7.5
7.5
7.5
7.5
EH2600IND
Full load (A)
-
-
21.5
20.7
-
34.8
Rating (kW)
-
-
11.0
11.0
-
11.0
EH2600C
Full load (A)
-
-
-
-
-
36.3
Rating (kW)
-
-
-
-
-
11.0
EH2600 T3X
Full load (A)
-
-
20.8
19.5
-
-
EH2600 T160/T4X
Rating (kW)
-
-
11.0
11.0
-
-
EH4200
Full load (A)
19.8
18.2
11.5
10.5
20.9
18.9
Rating (kW)
7.5
17.5
7.5
7.5
7.5
7.5
EH4200IND
Full load (A)
-
-
21.5
20.7
-
34.8
Rating (kW)
-
-
11.0
11.0
-
11.0
EH4200C
Full load (A)
-
-
-
-
-
36.3
Rating (kW)
-
-
-
-
-
11.0
EH4200 T3X
Full load (A)
-
-
20.8
19.5
-
-
EH4200 T160/T4X
Rating (kW)
-
-
11.0
11.0
-
-
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Page 11
460 V
60 Hz
2.8
1.5
4.4
2.2
5.4
3.0
5.0
3.0
-
-
9.5
7.5
17.4
11.0
18.1
11.0
-
-
9.5
7.5
17.4
11.0
18.1
11.0
-
-
Page 13
A301-51-880 Issue T
2.3

Performance

Table 8 - Performance data
Rotational speed:
-1
50 Hz electrical supply
0 to 2900 r min
-1
60 Hz electrical supply
0 to 3500 r min
5
Maximum outlet pressure (see
Section
1.2.4)
1000 mbar absolute, 1 x 10
Pressure differential across EH pump (determined by the hydrokinetic drive):
Pump
50 Hz electrical supply
60 Hz electrical supply
4
EH250/EH250IND
0 to 180 mbar
0 to 1.8 x 10
Pa
0 to 150 mbar
0 to 1.5 x 10
4
EH500/EH500IND
0 to 110 mbar
0 to 1.1 x 10
Pa
0 to 90 mbar
0 to 9 x 10
4
EH1200/EH1200IND
0 to 90 mbar
0 to 0.9 x 10
Pa
0 to 75 mbar
0 to 7.5 x 10
EH1200C
-
-
0 to 75 mbar
0 to 7.5 x 10
3
EH1200 T3/T160/T4X
0 to 76 mbar
0 to 7.6 x 10
Pa
-
-
3
EH2600
0 to 80 mbar
0 to 8 x 10
Pa
0 to 67 mbar
0 to 6.7 x 10
4
EH2600IND
0 to 120 mbar
0 to 1.2 x 10
Pa
0 to 67 mbar
0 to 6.7 x 10
EH2600C
-
-
0 to 67 mbar
0 to 6.7 x 10
4
EH2600 T3X
0 to 114 mbar
0 to 1.14 x 10
Pa
-
-
3
EH2600 T160/T4X
0 to 75 mbar
0 to 7.5 x 10
Pa
-
-
3
EH4200
0 to 60 mbar
0 to 6 x 10
Pa
0 to 50 mbar
0 to 5 x 10
3
EH4200IND
0 to 70 mbar
0 to 7 x 10
Pa
0 to 50 mbar
0 to 5 x 10
EH4200C
-
-
0 to 50 mbar
0 to 5 x 10
3
EH4200 T3X
0 to 64 mbar
0 to 6.4 x 10
Pa
-
-
3
EH4200 T160/T4X
0 to 52 mbar
0 to 5.2 x 10
Pa
-
-
2.4

Mechanical data

Table 9 - Mechanical data
Dimensions
See
Figure 3
to
10
Mass:
EH250
61 kg
EH1200
149 kg
EH250IND
66 kg
EH1200IND
149 kg
EH500
69 kg
EH1200C
170 kg
EH500IND
74 kg
EH1200 T3/T160/T4X
170 kg
EH2600
308 kg
EH4200IND
380 kg
EH2600IND
345 kg
EH4200C
425 kg
EH2600C
415 kg
EH4200 T3X
495 kg
EH2600 T3X
415 kg
EH4200 T160/T4X
495 kg
EH2600 T160/T4X
415 kg
Page 12
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A301-51-880 Issue T
2.6

Lubrication data

Note:
Edwards Material Safety Data Sheets for the oils and grease specified below are available on request.
Table 11 - Lubrication data
Recommended oil type
Hydrocarbon pumps
Ultragrade 20
PFPE pumps
Fomblin YVAC 16/6
*
Recommended grease type
Fomblin AR555
Oil capacity:
All EH250
All EH500
All EH1200
Gear-cover
-
-
1.25
Hydrokinetic drive/gearbox
1.5
1.5
2.4
Shaft-seal reservoir
0.125
0.125
0.125
All EH2600
All EH4200
Gear-cover
3.5
3.5
Hydrokinetic drive/gearbox
6.5
6.5
Shaft-seal reservoir
0.15
0.15
*
For use with all EH250 and EH500 pumps
2.7
Hydrokinetic drive/gearbox nitrogen supply (EH1200C, EH1200
T3/T160/T4X, EH2600C, EH2600 T3X, EH2600 T160/T4X,
EH4200C, EH4200 T3X, EH4200 T160/T4X only)
Table 12 - Hydrokenetic drive/gearbox purge nitrogen supply data
4
4
Regulated pressure
0.3 to 0.5 bar gauge, 3 x 10
to 5 x 10
Pa
2.8

Cooling-water data

Notes:
1. If any EH1200, EH2600 or EH4200 model pump is used in an ATEX system, the EH pump must be operated
with cooling-water. This is safety critical, and your system must incorporate a flow-switch (connected
to the cooling-water outlet) which monitors the flow rate of the cooling-water through the EH pump;
the flow-switch must be connected to your control system, which must be configured to shut down the
EH pump when the cooling-water flow through the EH pump is too low (see
Table 14
for the minimum
cooling-water flow rates). Refer to the ATEX instruction manual for further details.
2. If any EH1200 model pump is not part of an ATEX system, you can operate the EH pump continuously
2
without cooling-water if the inlet pressure is kept below 5 mbar (5 x 10
Pa) and the pumpdown time is
no longer than 10 minutes.
Table 13 - Cooling water supply data: EH pumps in non-ATEX systems
Recommended cooling-water flow
(with inlet temperature of 20 ºC)
-1
EH1200 pumps
3 l min
-1
EH2600 pumps
6 l min
-1
EH4200 pumps
6 l min
Recommended cooling-water supply pressure
2 to 6 bar gauge, 3 to 7 bar absolute,
5
5
3 x 10
to 7 x 10
Pa
Permissible temperature range
5 to 35 ºC
Page 14
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Pa
4
Pa
3
Pa
3
Pa
3
Pa
3
Pa
3
Pa
3
Pa
3
Pa
3
Pa
3
Pa

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents