3. Technical data

WARNING:
If the pump is operated outside the specific limits, the pump housing may become
hot.

3.1 Operating and storage conditions

Table 1 Operating and storage conditions
Ambient temperature range (operation)
Maximum surface temperature of pump body
under normal operating conditions and maxi-
mum ambient temperature
Maximum humidity (operation)
Ambient temperature range (storage)
Pollution
Installation
Altitude restriction
Area of use
If the storage time is less than 2 years start the pump by instruction described in
storage for less than 2 years
If the storage time is more than 2 years continue by instruction described in
storage for more than 2 years

3.2 Performance

Table 2 General characteristics
Maximum pumping speed
Maximum permitted continuous inlet pressure
Maximum inlet peak pressure
Maximum permitted continuous exhaust pres-
sure
Maximum permitted gas ballast inlet pressure
Maximum chamber volume to pump down from
atmospheric pressure
Maximum chamber volume for cyclic duty‑maxi-
mum 6 cycles per hour
A73001880_P
A73001880_P - Technical data
on page 34.
on page 34.
Page 12
+ 10 °C to + 40 °C
+ 40 °C to + 65 °C
90% RH
- 30 °C to + 70 °C
Pollution degree 2
Installation category II
UL/CSA approved maximum 2000 m
(3000 m for E variant self certified)
Indoor use
3
35 m
/h
40 mbar
(1000 mbar for E variant)*
4 bar(g)
0.2 bar(g)
0.5 bar(g)
100 litres†
50 litres†
05/2022 - ©Edwards Limited
Pump
Pump