A301-51-880 Issue T
6. Connect the wires of the cable to the appropriate terminals, as shown in the wiring instructions supplied with
the pump motor, or if in doubt the appropriate Figure specified in
Table
20.
7. Tighten the cable-gland.
8. If you have a chemical or ATEX compliant EH pump, continue at
Section 3.6.3
to connect the motor thermistors,
otherwise refit the terminal-box cover to the motor.
Table 19 - Motor cable-gland hole sizes
Electrical supply cable-
Thermistors cable-gland
*
Pump type
Motor frame size
gland hole size (ISO)
hole size (ISO)
Safe area EH pumps
90, 100
20
-
132
25
-
160
32
-
Chemical EH pumps and ATEX
100
20
20
compliant
160
32
20
*
As shown on the motor label.
3.6.3

Connect the motor thermistors (chemical and ATEX compliant EH pumps only)

The flameproof motors on all chemical and ATEX compliant EH pumps incorporate thermistors.
You must connect the thermistor terminals in the motor to a suitable control circuit, to shut down the EH pump
system if the motor temperature is too high. An example control circuit is shown in
Figure
12.
You must use a suitable two-wire cable and a suitable cable-gland (see Step 2) to connect the thermistors cable (from
your control circuit) to the thermistor terminals in the motor.
Use the following procedure to connect the thermistor terminals to the control circuit.
1. Remove the plug from the cable-entry hole that you will use for the thermistors cable. (If there is more than one
cable-entry hole, choose the most suitable hole for your application.)
2. Fit a suitable cable-gland to the cable-entry hole. The cable-gland (and adaptor, if fitted) must provide a
protective seal to IP44 (or higher), as defined by IEC 529. Refer to
Table 19
for the cable-gland hole sizes.
3. Pass the thermistors cable through the cable-gland.
4. Connect the two wires of the cable to the appropriate terminals, as shown in
Figure 13
to
21
(refer to
5. Tighten the cable-gland.
6. Refit the terminal-box cover to the motor.
7. Connect the thermistor wires to your control circuit.
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A301-51-880 Issue T
Table 20 - Electrical supply connection configurations
Motor
Motor Item
Motor voltage (V)
Motor
Frequency
Configuration
*
supplier
Number
(connection)
power
(Hz)
A071-12-004
1.5 kW
460
60
A
A071-13-076
2.2 kW
Leroy
A071-12-004
1.5 kW
208-230
60
B
A071-13-076
2.2 kW
A071-12-003
1.5 kW
A071-14-001
3 kW
Brook
A071-12-024
1.5 kW
380-415
50
C
A071-14-020
3 kW
A071-13-075
2.2 kW
Leroy
A071-14-006
3 kW
A071-12-003
1.5 kW
A071-14-001
3 kW
Brook
A071-12-024
1.5 kW
220-240
50
D
A071-14-020
3 kW
A071-13-075
2.2 kW
Leroy
A071-14-006
3 kW
WEG
A071-18-017
380-415 (delta)
11 kW
50
D
Leroy
A071-18-015
380-415 (delta)
11 kW
50
D
A071-18-021
11 kW
380-415
50
D
(direct delta start)
A071-18-015
11 kW
A071-12-004
1.5 kW
460
60
E
(star)
Brook
A071-12-025
1.5 kW
A071-12-004
1.5 kW
208-230
60
F
(double star)
A071-12-025
1.5 kW
A071-14-012
460
4 h.p.
60
G
A071-18-019
460 (delta)
11 kW
60
E
WEG
A071-18-019
230 (double delta)
11 kW
60
H
A071-14-002
4 h.p.
A071-14-021
4 h.p.
A071-18-016
15 h.p.
460
60
E
(delta)
A071-18-022
15 h.p.
A071-17-002
10 h.p.
A071-17-029
10 h.p.
Brook
A071-14-002
4 h.p.
A071-14-021
4 h.p.
208-230
60
I
(double delta)
A071-17-002
10 h.p.
A071-17-029
10 h.p.
A071-18-016
15 h.p.
230
60
I
(double delta)
A071-18-022
15 h.p.
*
As shown on the label on the motor.
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Table
20).
Page 31
Refer to
Figure
13
14
15
16
16
16
16
17
18
19
17
20
17
21
21
Page 33
A301-51-880 Issue T
Figure 12 - Example control circuit
1. Electrical supply isolator
5. Start switch
9. Pump motor
2. +ve control side
6. Fault indicator lamp
10. Contactor
3. Thermistor relay
7. Pump contactor
11. Circuit breaker
4. Stop switch
8. 0 V control side
Page 32
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A301-51-880 Issue T
Figure 13 - Electrical supply configuration A
1. Thermistors cable
5. Electrical supply cable
Note:
The thermistor terminals may
2. Cable-gland
6. To control circuit
be annotated "T1" and "T2"
3. Terminal/wire markings
instead of "P1" and "P2".
4. Cable-gland
Figure 14 - Electrical supply configuration B
1. Thermistors cable
6. Electrical supply cable
Note:
The thermistor terminals may
2. Cable-gland
7. To control circuit
be annotated "T1" and "T2"
instead of "P1" and "P2".
3. Links
4. Terminal/wire markings
5. Cable-gland
Page 34
© Edwards Limited 2007. All rights reserved.