M518-00-880 Issue A Instruction Manual CXS Dry Pump and EH Booster Pump Combination Systems...
Page 2
Flame arresters. Performance requirements, test methods and limits for use EN12874:2001* Flame Arresters – Performance Requirements, Test Methods and Limits of use *CXS 160 and 250 Pump systems including flame arresters were tested in accordance with this standard. Standard now withdrawn. and fulfils all the relevant provisions of...
Page 3
P200-10-078 Issue A Materials Declaration In accordance with the requirements of the Chinese regulatory requirement on the Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products Order No. 32 (also known as ‘China RoHS2’) and SJ/T 11364 Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products: Product Labels Product...
Introduction Scope and definitions Edwards CXS dry pumps factory fitted with Edwards EH Mechanical boosters are intended to be installed, commissioned and operated as complete combination systems. This instruction manual details only the specific information for these pumps operating together as combination systems.
RF Earth (ground). The following warning only appears in this manual: Warning - Pressurised. Material safety data sheets for chemicals supplied by Edwards can be obtained by contacting Edwards, or on www.edwardsvacuum.com. Applications CXS/EH Pump combination systems are suitable for a wide range of industrial applications. Edwards has a dedicated team of applications engineers who can help you determine the best CXS/EH Pump combination system for your application.
M518-00-880 Issue A Flammable atmospheres There are two flammable zones (atmospheres) associated with Edwards dry pump systems. The definitions of these two zones are as follows: External The atmosphere around the outside of the Edwards system and everywhere within the equipment where it is possible for this atmosphere to be present.
Under transient conditions such as power on or pump acceleration. ii) With abnormal supply configurations such as a missing or earthed phase or unbalanced supply voltages. Contact Edwards for more information about configuration requirements for earth leakage reduction. Cooling-water data The single interface connections distribute the require coolant flows to the CXS Pump and EH Booster.
CXS Manual M52800880. No other positions or modifications are permitted without consulting Edwards. Otherwise, there may be a risk of injury or death to people and damage to equipment and facilities.
EH pump, you must fit a suitable inlet filter. The inlet connection is made with a standard ISO flange and Edwards trapped O-ring. Details of connecting to the inlet of the CXS/EH combination system are given in the Manual A30151880.
Perchlorate Material - special handling may apply, refer to www.dtsc.ca.gov/hazardouswaste/perchlorate/ Edwards products are supported by a worldwide network of Edwards Service Centres. Each Service Centre offers a wide range of options including disposal. Refer to Section 7.2...
Download the latest documents from www.edwardsvacuum.com/HSForms/, follow the procedure in HS1, fill in the electronic HS2 form, print it, sign it, and return the signed copy to Edwards. Note: If we do not receive a completed HS2 form, we will not accept the return of the...