A301-51-880 Issue T
Table 14 - Cooling-water supply data: EH pumps in ATEX systems
Minimum cooling-water flow
(with inlet temperature of 20 ºC)
-1
EH1200 T3/T160/T4X
2 l min
-1
EH2600 T3/EH2600 T160/T4X
4 l min
-1
EH4200 T3/EH4200 T160/T4X
4 l min
Recommended cooling-water supply pressure
2 to 6 bar gauge, 3 to 7 bar absolute,
5
5
3 x 10
to 7 x 10
Pa
Permissible temperature range
5 to 35 ºC
2.9

Noise and vibration data

Table 15 - Noise and vibration data
-1
Vibration level
< 1.8 mm s
r.m.s. in the range 10 to 1000 Hz
Continuous A-weighted sound pressure level
measured at 1 metre from the EH pump:
EH250
EH500
EH1200
EH2600
EH4200
72 dB(A)
72 dB(A)
77 dB(A)
83 dB(A)
83 dB(A)
2.10

Connections

Table 16 - Connections
Cooling-water connections:
3
Inlet
/
inch BSP male
8
3
Outlet
/
inch BSP male
8
*
1
Hydrokinetic drive/gearbox purge connection
/
inch compression fitting
4
Vacuum connections:
EH250
EH500
EH1200
EH2600
EH4200
Inlet
ISO63
ISO100
ISO160
ISO160
ISO250
Outlet
ISO40
ISO63
ISO100
ISO100
ISO100
*
Chemical and ATEX compliant pumps only.
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A301-51-880 Issue T
Figure 3 - EH250/EH250IND dimensions (mm)*
EH250
EH250IND
1. Lifting-bolt
A
682
709
2. External evacuation port
B
270
270
C
183
190
*
The dimensions given in
Figure 3
assume that Leroy is used for both the 1.5 and 2.2 KW motors.
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Page 15
Page 17
A301-51-880 Issue T
2.11
Materials of construction of components exposed to pumped
gases
Table 17 - Materials of construction
Stator and headplates
Grey cast iron, grade 250 (BS1452)
Rotors
SG iron, grade 420/12 (BS2789)
Hydrokinetic drive/gearbox cover
Aluminium LM25TF (BS1490)
Housing 'O' rings
Viton
Hydrokinetic drive/gearbox shaft-seals
Viton
Internal pump shaft-seals
PTFE (polytetrafluoroethylene)
*
Hydrokinetic drive/gears cooling coils
Copper/brass
After-cooler and swept volume
Nickel plated copper/brass
Headplate jointing compound
Loctite 518
*
All EH1200, EH2600 and EH4200 models.
All EH2600 and EH4200 models.
2.12

Item Numbers

Table 18 - Item numbers
220-240 V/380-415 V
208-230 V/460 V
*
3-phase, 50 Hz
3-phase, 60 Hz
Pump(s)
Type
Hydrocarbon
PFPE
Hydrocarbon
PFPE
EH250
SA
-
A301-53-935
-
A301-54-936
EH250IND
SA
A301-51-945
-
A301-52-946
EH500
SA
-
A302-73-935
-
A302-74-936
EH500IND
SA
A302-71-945
-
A302-72-946
EH1200
SA
-
A305-92-935
-
A305-93-936
EH1200IND
SA
A305-90-935
-
A305-91-936
EH1200C
FP
-
-
A305-56-982
EH1200 T3/T160/T4X
FP
A305-57-900
-
-
EH2600
SA
-
A307-53-935
-
A307-54-936
**
EH2600IND
SA
A307-75-946
-
A307-76-982
**
EH2600C
FP
-
-
A307-56-982
EH2600 T3X
FP
A307-41-935
-
-
EH2600 T160/T4X
FP
A307-79-900
-
-
EH4200
SA
-
-
-
**
EH4200IND
SA
A309-75-946
-
A309-76-982
**
EH4200C
FP
-
-
A309-56-982
EH4200 T3X
FP
A309-41-935
-
-
EH4200 T160/T4X
FP
A309-79-900
-
-
*
SA = Safe area, FP = Flameproof
460 V only
380-415 V only
**
230/460 V only
Page 16
© Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A301-51-880 Issue T
Figure 4 - EH500/EH500IND dimensions (mm)*
EH500
EH500IND
A
770
797
1. Lifting-bolts
B
234
252
2. External evacuation port
C
183
190
*
The dimensions given in
Figure 4
assume that Leroy is used for both the 1.5 and 2.2 KW motors.
Page 18