Microphone Controls; Mic Volume And Mute; Talk-Over - Extron electronics MPS 602 User Manual

Media presentation switcher
Hide thumbs Also See for MPS 602:
Table of Contents

Advertisement

Microphone Controls

Mic Volume and Mute

INPUTS
3
4
5
6

Talk-over

Mic volume and mute are controlled from the front panel (see figure 15). The mic MUTE
button (
) toggles the mic input on and off. The corresponding red Indicator (
A
when mic volume is muted.
When the mic input is unmuted, it is mixed with the program audio output at a level set by
the mic volume rotary encoder (
control. Clockwise rotation increases and counterclockwise decreases mic volume.
A A B B C C
MIC
MUTE
Figure 15.
Mic Volume and Mute
The MPS 602 features talk-over to automatically reduce program audio volume
when microphone audio is present. When the switcher detects an audio signal from the
Mic input, it immediately reduces or "ducks" the program audio volume. When microphone
audio is not detected for a period of one second, it increases the program audio level at a
rate of 3 dB per second until the program audio returns to the original volume level.
Ducking is adjustable from 0 to 30 dB (default: 6 dB). Mic level threshold, the level at which
ducking is initiated, is adjusted from 0 to 30 dB (default: 8 dB). Both are adjusted with SIS
Connection Options
commands (see
Program audio ducking level in talk-over mode
threshold
on page 52), or using the PCS software application (see
Using PCS
on page 41).
To adjust microphone threshold and program audio ducking levels via RS-232 or USB:
1.
Adjust program audio for nominal listening levels (see
page 17).
2.
Turn on the microphone by pressing the Mic Mute button (mute Indicator goes out).
3.
Speak into the microphone in a normal voice. The main program level drops
immediately.
a.
If the microphone consistently cuts off the beginning of speech, or cuts out sections
of audio, adjust the threshold level (see
b.
If the program level is too high during talk-over, but is the proper level for times
where talk-over is not active, adjust the ducking level (see
ducking level in talk-over mode
4.
Stop speaking into the microphone. The main program audio gradually (within 2 to 4
seconds) increases to the previous level. If not, increase the threshold level (see
talk-over threshold
on page 52).
). Mic volume is adjusted at a rate of 1 dB per step of the
C
PROGRAM AUDIO
MUTE
MPS SERIES
MEDIA PRESENTATION SWITCHER
on page 44) using RS-232 or USB control (see
on page 51 and
Mic talk-over threshold
on page 51).
) lights
B
Mic talk-over
Talk-over Control
Program Audio Volume
on
on page 52).
Program audio
Mic
MPS 602 • Operation
19

Advertisement

Table of Contents
loading

Table of Contents