Summary of Contents for Extron electronics MPS 409
Page 1
User Guide Switchers MPS 409 Media Presentation Switcher 68-1833-01 Rev. A 07 10...
Page 2
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and mainte- nance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
Page 3
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.
MPS 409 integrates several video switchers into one product. the MPS 409 is a 2x1 VGA and audio switcher, a 2x1 DVI-D video and audio switcher, a 3x1 HDMI and audio switcher, and a 2x1 composite video and audio switcher. the MPS 409 can also function as a 9x1 video switcher and includes a mic/line input with phantom power, mic audio ducking (talkover), executive front panel lockout, and a program audio output.
Page 8
• Front-panel Mic and Program Audio output volume controls — to streamline audio setup, the MPS 409 features front-panel Mic and program audio output volume controls which allow for easy and separate adjustment of Mic and program audio volumes. this eliminates the need for audio preamplifiers in many system designs.
Page 9
Extron 0 .2 0 -2 MPS 409 Digital Media /6 0 Presentation Switcher with DVI Output Figure 1. MPS 409 Application Diagram Composite /L IN -2 3 M IC /L IN M IC D IO V ID A /Y I- D...
Cabling the MPS 409 Switcher Mounting the Switcher the MPS 409 is housed in 1U, full rack width metal enclosure rack- or desk-mountable. the MBD 149 1U through-desk and rack mounting kit (#70-077-03) is included with the switchers. the switchers may also be surface-mounted under a table, desk, or podium, or on a wall, using the optional MBU 149 1U under-desk mounting kit (#70-222-01).
Page 11
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips). MPS 409 • Installation...
R-Y (Pr), blue color channels are used for B-Y (Pb), and green color channels are used for Y. NOTE: the MPS 409 does not scale or convert video. the input signal format will also be the output format. VGA video output — One 15-pin HD connector with the selected VGA/YUV video output.
Page 13
Do not tin the mic wire leads before installing into the connector. tinned wires are not as secure in the connector and could be pulled out. Plug the 3-pole captive screw connector into the MPS 409. RS-232 remote — One female 9-pin D connector for a host computer or a controller using Simple Instruction Set (SIS) or Windows-based control software.
Page 14
Connecting the 5-pole captive screw stereo output connector Balanced or unbalanced program audio output is available on the MPS 409 using a 3.5 mm, 5-pole captive screw connector. Refer to the following illustration for proper wiring. CAUTION: For unbalanced audio output, connect sleeves to the center ground pin.
Cabling the MPS 409 Switcher the MPS switcher can be connected to as many as 9 input devices simultaneously. It can output to as many as four devices (three in combine mode) simultaneously. Outputs can be configured for simultaneous outputs from each of the four input groups, VGA/YUV, DVI-D, HDMI, composite or one at a time from a selection of the nine inputs.
Operation this section discusses how to connect, configure, and operate the MPS 409. topics that are covered include: • Front Panel Features • Front Panel Operation • Program Audio • EDID Minder • HDCP Front Panel Features VGA/YUV INPUTS DVI INPUTS...
SINGLE SEPARATE COMBINE DVI/HDMI Press and release for 3 seconds Separate Mode ) for 3 seconds, then press and release the Combine DVI/HDMI button HDMI INPUTS VIDEO INPUTS MUTE ). the HDMI INPUTS VIDEO INPUTS MUTE MPS 409 • Operation...
LED Lit: LED Lit: LED Lit: for 3 seconds Single Separate Combine Mode Mode Mode NOTE: Switcher is shown in single-combined mode. Front Panel Button/LED Functions During View Mode HDMI INPUTS VIDEO INPUTS MUTE MPS 409 • Operation MUTE DIGIT...
MODE SINGLE SEPARATE COMBINE DVI/HDMI Program Audio on page 15 for more details. VGA/YUV INPUTS DVI INPUTS HDMI INPUTS MODE SINGLE SEPARATE COMBINE DVI/HDMI VIDEO INPUTS MUTE LED blinking VIDEO INPUTS MUTE Blinking Program Audio Breakaway MPS 409 • Operation...
Combine mode switches a selected HDMI/DVI input to the HDMI output, deactivating the DVI audio and video outputs. this enables the MPS 409 to function as one 5x1 HDMI/DVI and audio switcher, adding VGA/YUV and Video inputs. Combine mode can be used whether the switcher is in separate or single switch mode.
Program Audio Selection (HDMI Program Audio Selection Shown) Program Audio Breakaway on page 23 HDMI INPUTS VIDEO INPUTS PROGRAM AUDIO VIDEO INPUTS MUTE MUTE DIGITAL MEDIA PRESENTATION SWITCHER PROGRAM AUDIO MUTE MUTE MPS 409 DIGITAL MEDIA PRESENTATION SWITCHER MPS 409 • Operation MPS 409...
3 seconds, the switcher times out and the gain/attenuation mode is exited. Front Panel LEDs = on, = blinking fast, = blinking slowly, = off MPS 409 • Operation...
Figure 17. Talk-over the MPS 409 also features talk-over to automatically reduce program audio volume when microphone audio is present allowing the microphone audio to be heard more intelligibly. When the switcher detects an audio signal from the Mic input, it immediately reduces or "ducks"...
When the HDMI/DVI combine mode is enabled at the same time EDID Minder is enabled on the DVI inputs, the EDID will be updated with the HDMI output device EDID. Default EDID 1024 x 768 @ 60 Hz 1024 x 768 @ 60 Hz Default EDID Resolutions MPS 409 • Operation...
Updating Firmware Connection Options the MPS 409 can be remotely connected via a host computer or other device (such as a control system) attached to the rear panel RS-232 port or the front panel USB Config port. the switcher can be set up and controlled using SIS (Simple Instruction Set) commands. SIS commands may be executed using the Extron DataViewer program, found on the Software Products DVD included with the product or at www.extron.com.
A string is one or more characters. MPS Switcher-initiated Messages When a local event occurs, such as a front panel operation, the MPS switcher responds by sending a message to the host. the MPS 409-initiated messages are listed below (underlined). Boot-up messages (c) Copyright 2010, Extron Electronics, MPS 409, Vx.xx ]...
128 or 256 Byte EDID raw HEX (text form) native resolution and refresh rate from selected EDID MPS 409 name. Name is a text string of up to 24 alpha-numeric characters. MPS 409 • SIS Programming and Control - 1) times 4 +...
Page 29
X1#] •Aud X1#] •Aud X1#] •Aud X1#] –G •Aud X1#] MPS 409 • SIS Programming and Control Switcher- Description initiated messages Group and input selected. = Group 1 through 4 (1 = VGA, 2 = DVI, 3 = HDMI, 4 = Composite).
Page 30
X% ] X^ ] X# ] X# ] X* ] X* ] X* ] X* ] MPS 409 • SIS Programming and Control Switcher- Description initiated messages Adjusts how much = 0 to 30 dB) the program audio ducks (automatically decreases) in talk over mode.
Page 32
* EDID X1* ] * EDID = 3 or 4) will give an error (E13). = 12-13 are 256-Byte EDID files, each containing a CEA 861 extension block, with MPS 409 • SIS Programming and Control Switcher- Description initiated messages...
Page 33
50 Hz 1080p, basic audio 60 Hz 1080p, full audio 50 Hz 1080p, full audio 60 Hz User loaded MPS 409 • SIS Programming and Control Pixel Clock 40 MHz 65 MHz 79.5 MHz 83.5 MHz 108 MHz 85.5 MHz 106.5 MHz...
Updating Firmware the Firmware Loader program allows replacing firmware without taking the MPS 409 out of service. First obtain the latest firmware, then update the firmware using Firmware Loader. Download the latest firmware file: Visit the Extron Web site, www.extron.com. From the Product page, locate and select the MPS 409 (in the left column select Switchers >...
Reference Information this section discusses the specifications, part numbers, and accessories for the MPS 409. topics that are covered, include: • Specifications • Part Numbers and Accessories • Cables and Connectors Specifications Video — VGA Gain ... Unity Bandwidth ... 350 MHz (-3 dB) Crosstalk ...
(Depth excludes connectors and knobs. Width excludes brackets.) Product weight ... 7.0 lbs (3.2 kg) Shipping weight ... 10 lbs (5 kg) Vibration ... IStA 1A in carton (International Safe transit Association) ® ™ (SIS ™ MPS 409 • Reference Information...
Page 39
EMI/EMC ... CE, C-tick, ICES, FCC Class A, VCCI MtBF ... 30,000 hours Warranty ... 3 years parts and labor NOTE: All nominal levels are at ±10%. NOTE: Specifications are subject to change without notice. MPS 409 • Reference Information...
CSR 6, captive screw male to 2 RCA female adapter MSR 6, 3.5 mm mini stereo male to 2 RCA female adapter IR 102 Universal Remote Control Kit Replacement part number 60-1012-01 70-077-03 Part number 100-229-01 26-533-xx 26-575-01 26-592-01 70-224-10 MPS 409 • Reference Information...
StP20-2, Serial Control/Audio Cable, non-plenum Part number 26-490-xx Part number 26-533-xx Part number 26-316-xx Part number 26-649-xx Part number 26-650-xx Part number 26-614-xx Part number 26-571-01, -02, -06, Part number 22-123-03 22-020-02 22-175-02 22-185-02 22-145-02 22-098-02 22-024-01 22-160-03 22-161-03 MPS 409 • Reference Information...
3.5 mm Mini Stereo-HQ, Male Stereo Audio BNC compression connectors (qty. = 50) Mini HR, Male-nickel RCA compression connectors (qty. = 50) Mini HR, Male-nickel Part number 100-250-01 100-256-01 Part number 100-333-01 100-334-01 100-332-01 100-331-01 Part number 100-186-01 Part number 100-302-01 MPS 409 • Reference Information...
Page 43
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to: USA, Canada, South America,...
Need help?
Do you have a question about the MPS 409 and is the answer not in the manual?