Packet Error - Siemens SCALANCE X-200 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

Menus in the WBM
5.5 the Statistics menu
5.5.4

Packet Error

Statistics Packet Error - Counting and evaluation of transmission errors
This page shows information on any errors that may have occurred and allows diagnostics
for the port on which the error occurred. You can reset the error counters with the "Reset
Counters" button.
If you click on an entry in the Port column, the Statistics Packet Error Graphic is displayed for
the selected port. You then see a graphical representation of the counter value.
Figure 5-52
Statistics Packet Error (The "Fragmented" column is only present with devices without the IRT function.)
The following errors can be detected:
CRC
Packets with a valid length but bad checksum.
Undersize
Packets too short with valid checksum.
Oversize
Packets too long with valid checksum.
Fragmented (Only with devices without the IRT function.)

 P ackets with a length less than 64 bytes and a bad CRC checksum.
Jabbers
Packets too long without valid checksum.