Siemens SCALANCE X-200 Configuration Manual page 121

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

Setting the power limits
In the first table, you can set the limits for the received power and the power loss for the
available ports.
Port
Shows the available optical ports.
Rx Power Maintenance [1/10 dBm]
● required
Enter the value at which you want to be informed of deterioration of the received power
the first time.
● demanded
Enter the value at which you want to be informed of deterioration of the received power
the second time.
Power loss Maintenance [1/10 dB]
● required
Enter the value at which you want to be informed about the power loss of the connection
the first time.
● demanded
Enter the value at which you want to be informed about the power loss of the connection
the second time.
Setting and status of the ports
In the second table, you can enable or disable Fiber Monitoring for the available ports and
monitor the status of the ports.
Port
Shows the available optical ports.
State
Enable or disable FM.
Rx Power State
● disabled
FM is disabled.
● ok
The value for the received power of the optical link is OK.
● maintenance required
Check the link.
An event is triggered.
SCALANCE X-200