Siemens SCALANCE X-200 Configuration Manual page 151

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

Collisions
Indicates the number of collisions that have occurred.
Note
X-200IRT IE switches work in the cut-through mode.
If a frame is received with a bad checksum, the forwarding of the frame is aborted
prematurely and the frame is therefore shortened. The counter for CRC errors is
incremented.
If the frame involved is a frame with a length of 64 bytes, the counter for undersize errors is
also incremented due to the shortening of the frame
Syntax of the Command Line Interface
Table 5- 42
Command
errors
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
Statistic Packet Error - CLI\INFORM>
Description
Displays statistical information on received errors.
Menus in the WBM
5.5 the Statistics menu
Comment
151