Menus in the WBM
5.3 The Agent menu
Enter the following values for the end of daylight saving time:
● Month
● Day
● Time of day in hours
Syntax of the Command Line Interface
Table 5- 25
Command
info
recurring <start
date> <end date>
date <yyyy> <start
date> <end date>
delete <index>
108
Daylight Saving Time Table - CLI\AGENT\TIME\DST>
Description
Shows information about the time zone and
the daylight saving time changeover.
Creates an entry of the type "Recurring".
You need to enter the following information for
the <start date > and <end date >:
1-5 or Last
Weekday
Month
Hour
Creates an entry of the type "Date".
For the <start date> and <end date> parame-
ters, enter the month, day and hour in the
following form:
mmddhh
Deletes an entry. The index of the entry to be
deleted must be obtained with the "info" com-
mand.
Comment
Administrator only
Example:
recurring last sunday march
02
last sunday october 03
Administrator only
Example:
date 2010 040102 100103
Administrator only