Syntax of the Command Line Interface
Table 5- 21
Command
info
scontrol [C|A]
sclose [yes|no]
setec
<Event|Index> <E|D> <E|D>
<E|D>
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
Agent Event Configuration - CLI\AGENT\EVENT>
Description
Shows the current event configuration.
Selects how the signaling contact works:
Conventional
•
An error/fault is displayed by the LED and
the signaling contact opens.
Aligned
•
The signaling contact can be opened or
closed as required regardless of a
fault/error.
Switches the signaling contact, if this in
"aligned" mode:
Yes
•
The contact is closed.
No:
•
The contact is opened
Specifies how an IE switch reacts to system
events. You can enter the following values
for the <Event> parameter:
CW
LC
AF
PM
FC
RD
SB
LD
FM
PO
If an event is specified, the configured ac-
tions are formed for each event.
With the two parameters <E> or <D>, you
configure the reactions of the IE switch in the
order:
E-mail
•
Trap
•
Entry in the log table
•
Example: If you only want to send an e-mail
when there is a Link Change, enter the fol-
lowing command:
setec LC E D D
Cold/Warm Start
Link Change
Authentication Failure
Power M12 Change
Fault State Change
Redundancy Event
Standby Event
Loop Detection
FMP Event
POF Event
Menus in the WBM
5.3 The Agent menu
Comment
Administrator only.
Administrator only.
Administrator only.
97