2.5 System Parameters
Value Range
100 ms–9900 ms, units 100 ms
Pause Time for ";"
Specifies the pause time for ";" used in call sequences.
Value Range
100 ms–9900 ms, units 100 ms
Outside Call Setup Sequence
Specifies the sequence of codes used by the VPS when calling a Trunk. You can set a maximum of
16 digits. The default value is "T". "T" indicates that the VPS will dial the telephone number only after
detecting a dial tone.
Example:
9, = (9) – 1 s wait – dial telephone number. "9" is the Trunk Access number.
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
,: Dial Pause for 1 s (default)
;: Dial Pause for 3 s (default)
0–9,
, #: Dial Codes
Message Waiting Notification
Determines how essential Message Waiting Notification features are carried out.
Outgoing Call Ports
Specifies the port numbers used for Message Waiting Notification Device feature. The VPS makes
outgoing calls using the port specified in this parameter. At least 1 port must be specified.
Note
•
The maximum number of ports depends on the VPS model.
Value Range
1–6 (KX-TVM50), 1–24 (KX-TVM200/KX-NCV200)
Feature Manual References
2.2.31 Message Waiting Notification—Device
120
Programming Manual
, # and special codes