Saving Settings; Saving Locally (And On The Aca) - Hirschmann RS20 User Manual

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Loading/saving settings

3.2 Saving settings

In the "Save" frame, you have the option to
save the current configuration on the device
save the current configuration in binary form in a file under the specified
URL, or as an editable and readable script
save the current configuration in binary form or as an editable and
readable script on the PC.
3.2.1

Saving locally (and on the ACA)

The device allows you to save the current configuration data in the local non-
volatile memory and the ACA.
Select the
Basics: Load/Save dialog.
In the "Save" frame, click "to Device".
Click on "Save".
The device saves the current configuration data in the local non-
volatile memory and, if an ACA is connected, also in the ACA.
enable
copy system:running-config
nvram:startup-config
Basic Configuration
Release 6.0 07/2010
Switch to the Privileged EXEC mode.
The device saves the current configuration data
in the local non-volatile memory and, if an ACA is
connected, also on the ACA.
3.2 Saving settings