Operation Diagnosis
9.3.1

Controlling the Signal Contact

With this mode you can remotely control every signal contact individually.
Application options:
Simulation of an error as an input for process control monitoring
equipment.
Remote control of a device via SNMP, such as switching on a camera.
Select the Diagnostics:Signal Contact 1/2) dialog.
In the "Mode Signal contact" frame, you select the "Manual setting"
mode to switch the contact manually.
Select "Opened" in the "Manual setting" frame to open the contact.
Select "Closed" in the "Manual setting" frame to close the contact.
enable
configure
signal-contact 1 mode manual Select the manual setting mode for signal contact
signal-contact 1 state open
signal-contact 1 state closed Close signal contact 1.
9.3.2
Monitoring the Device Status via the Signal
Contact
The "Device Status" option enables you, like in the operation monitoring, to
monitor the device state
via the signal contact.
Basic Configuration
Release 6.0 07/2010
Switch to the Privileged EXEC mode.
Switch to the Configuration mode.
1.
Open signal contact 1.
(see on page 181 "Monitoring the Device Status")
9.3 Out-of-band Signaling
185