2.9 Faulty Device Replacement

The device provides 2 plug-and-play solutions for replacing a faulty device
with a device of the same type (faulty device replacement):
Configuring the new device using an AutoConfiguration
page 39 "Loading the system configuration from the ACA")
configuration via DHCP Option 82
Server with Option 82")
In both cases, when the new device is started, it is given the same
configuration data that the replaced device had.
Note: If you replace a device with DIP switches, please ensure that the DIP
switch settings are identical.
Note: If you want to access the device via SSH, you also need an SSH key.
To transfer the SSH key of the old device to the new one, you have the
following options:
- If you have already created the key and saved it outside the device (e.g. on
your administration workstation), load the saved key onto the new device
(see on page 234 "Uploading the SSH Host
- Otherwise create a new SSH key and load it onto the new device
page 233 "Preparing Access via
identifies itself by means of another key.
52
2.9 Faulty Device Replacement
(see on page 224 "Setting up a DHCP
Key").
SSH"). Note that the new device now
Adapter(see on
or
(see on