Synchronizing the System Time in the
Network
ptp operation enable
ptp clock-mode v1-boundary-
clock
In this example, you have chosen the device with the IP address
10.0.1.112 as the PTP reference clock. You thus define this device as the
"Preferred Master".
Select the Time:PTP:Version1:Global dialog.
In the "Operation IEEE 1588 / PTP" frame, select true for the
"Preferred Master".
Click "Set" to temporarily save the entry in the configuration.
ptp v1 preferred-master true Define this device as the "Preferred Master".
Get PTP to apply the parameters.
In the Time:PTP:Version1:Global dialog, click on "Reinitialize"
so that PTP applies the parameters entered.
ptp v1 re-initialize
Basic Configuration
Release 6.0 07/2010
7.3 Precision Time Protocol
Switch on PTP globally.
Select PTP version and clock mode.
Apply PTP parameters.