Starter Motor Installation; Starter Relay Switch; Operation Inspection; Ground Line/Voltage Inspection - Honda rebel 250 Service Manual

Table of Contents

Advertisement

ELECTRIC
STARTER
INSTALLATION
Install
the
starter
motor
with the four
mounting
bolts.
Connect
the
starter
cable
to
the
motor and
tighten the
nut.
Install
the side spacer,
starter
drive
and
driven sprockets
and
chain (page
10-8).
STARTER RELAY SWITCH
OPERATION INSPECTION
Remove
the
right
side
cover (page
2
-
2
).
Shift
the transmission
into neutral.
Turn
the
ignition
switch
ON
and
depress
the
starter
switch
button.
The
coil
is
normal
if
the
starter
relay
switch
clicks.
If
the
switch
"CLICK"
is
not heard. Inspect
the relay switch
using
the
procedure below.
GROUND
LINE
INSPECTION
Disconnect
the
relay
connector.
Check
for
continuity
between
the
Green/Red
wire
and
ground.
If
there
is
continuity
when
the transmission
is in
neutral or
when
the
dutch
is
disengaged and the
side
stand switch
is
up.
the
ground
circuit is
normal
(In
neutral,
there
is
a
slight
resistance
due
to
the
diode).
VOLTAGE
INSPECTION
Connect
the
starter
relay
switch connecior.
Shift
the transmission
into neutral.
Measure
the voltage
between
the
Yellow/Red wire
() and
ground
at
the
starter
relay
switch connector.
There should be
battery voltage
only
when
the
starter
switch button
Is
depressed
with the
ignition
switch
is
ON.
17-10

Advertisement