7.10.3 Connecting the machine head

To connect the machine head:
1.
Insert the plug on the connecting cable for the machine head
into the socket of the respective control.

7.10.4 Establishing equipotential bonding

The grounding wire conducts away any static charging of the
machine head.
Fig. 47: Establishing equipotential bonding
(1) - Control grounding wire
(2) - Screw
To establish equipotential bonding:
1.
Tilt the machine head.
(3) - Motor grounding wire
(4) - Toothed lock washer