Programming
Operating Instructions 1767 - 00.0 - 12/2016
3.
Press.
 The LED of the
Use the D- or D+ button to set the reset value to 400.
4.
5.
Confirm your selection with
Press the D+ button repeatedly until 04 appears on the
6.
display:
Use parameter 04 to set the factor.
7.
Press.
 The LED of the
Use the D- or D+ button to set the factor to 20.
8.
9.
Confirm your selection with
10. Exit parameter mode with
 The bobbin stitch counter is at 8000.
In addition to A, there are 2 other bobbin stitch counters.
Use parameter 02 and 03, respectively, to set the reset value for
bobbin stitch counter B and C.
Reset the bobbin stitch counter with the
button flashes.
.
button flashes.
.
.
button.