Setup
Operating Instructions 1767 - 00.0 - 12/2016

7.11.2 Setting the operating pressure

NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical data ( p. 107) chapter for the permissi-
ble operating pressure. The operating pressure cannot deviate by
more than ± 0.5 bar.
Fig. 49: Setting the operating pressure
(1) - Pressure controller
To set the operating pressure:
1.
Pull the pressure controller (1) up.
(2) - Pressure gage
95