98
PERIODIC SERVICE
BCleaning Evacuator Valve
Open the evacuator valve to get rid of large particles of
dust and dirt.
(1) Evacuator valve
BChecking Dust Indicator
There is a dust indicator on the air cleaner body. If the red
signal on the dust indicator is visible, clean the element
immediately. (See "Cleaning Air Cleaner Primary
Element" in "EVERY 100 HOURS" in "PERIODIC
SERVICE" section.) Reset the red signal by pushing a
"RESET" button after cleaning.
(1) "RESET" button
(2) Dust indicator
(3) Red signal
BCleaning Grill, Radiator and Cooler
To avoid personal injury or death:
A Be sure to stop the engine before removing the
screen.
A The condenser and receiver become hot while
the air conditioner is running. Before checking
or cleaning them, wait long enough until they
cool down.
C Detaching the panel
1. Pull the upper part of the panel outward.
2. Raise the panel until pin (A) clears the hole, and take
out the panel.
3. Attaching the panel is performed vice versa.
(1) Panel
(2) Pin (A)
(3) Hole